Skip to main navigation Skip to search Skip to main content

A comparison between visual, intraoral scanner, and spectrophotometer shade matching: A clinical study

  • Walleska Feijó Liberato
  • , Isadora Carvalho Barreto
  • , Priscila Paganini Costa
  • , Cristina Costa de Almeida
  • , Welson Pimentel
  • , Rodrigo Tiossi

Research output: Contribution to journal › Article › peer-review

Abstract

Statement of problem: Visual shade matching is subjective and a cause of concern for clinicians. Different measurement devices have been developed to assist in tooth color selection and to achieve better esthetic results. However, consensus is lacking as to which method of tooth shade selection provides more predictable results. Purpose: The purpose of this clinical study was to compare the reliability of different visual and instrumental methods for dental shade matching. Material and methods: Visual shade matching was performed by 3 experienced clinicians using 2 different shade guides (VITA Classical A1-D4 and VITA Toothguide 3D-MASTER with 29 tabs; VITA Zahnfabrik) with and without the aid of a light-correcting device (Smile Lite; Smile Line). An intraoral scanner (TRIOS; 3Shape A/S) and a spectrophotometer (VITA Easyshade Advance 4.0; VITA Zahnfabrik) were also used for color shade matching. The instrumental methods were repeated 3 times to determine repeatability. Shade-matching sessions for each method were performed under controlled lighting on the middle third of the maxillary right central incisor of 28 participants. The Fleiss' kappa statistical test was used to assess the reliability of each method. The weighted kappa statistical test was used to assess the agreement between the shades matched by different methods (α=.05). Results: Instrumental methods were more accurate than visual methods. The best performance was found for the intraoral scanner configured for the 3D-MASTER scale (Fleiss' kappa value of .874) and for the spectrophotometer configured for the VITA Classical scale (Fleiss' kappa value of .805). The best visual shade-matching method was the VITA Classical scale associated with the light-correcting device (Fleiss' kappa value of .322). The Classical scale without the light-correcting device showed the poorest reliability (Fleiss' kappa value of .177) (P<.05). Conclusions: Instrumental methods for color shade matching were more reliable than the visual methods tested.

Original languageEnglish
Pages (from-to)271-275
Number of pages5
JournalJournal of Prosthetic Dentistry
Volume121
Issue number2
DOIs
StatePublished - Feb 2019
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2018 Editorial Council for the Journal of Prosthetic Dentistry

ASJC Scopus Subject Areas

  • Oral Surgery
  • General Dentistry

Fingerprint

Dive into the research topics of 'A comparison between visual, intraoral scanner, and spectrophotometer shade matching: A clinical study'. Together they form a unique fingerprint.

Cite this