Skip to main navigation Skip to search Skip to main content

A "sweet-spot" for fluid-induced oscillations in the conditioning of stem cell-based engineered heart valve tissues

  • Alexander Williams
  • , Sana Nasim
  • , Manuel Salinas
  • , Arash Moshkforoush
  • , Nikolaos Tsoukias
  • , Sharan Ramaswamy

    Research output: Contribution to journal › Article › peer-review

    Abstract

    Fluid-induced shear stresses are involved in the development of cardiovascular tissues. In a tissue engineering framework, this stimulus has also been considered as a mechanical regulator of stem cell differentiation. We recently demonstrated that the fluid-oscillating effect in combination with a physiologically-relevant shear stress magnitude contributes to the formation of stem cell-derived de novo heart valve tissues. However, the range of oscillations necessary to induce favorable gene expression and engineered tissue formation is unknown. In this study, we took a computational approach to establish a range of oscillatory shear stresses that may optimize in vitro valvular tissue growth. Taking a biomimetic approach, three physiologically-relevant flow waveforms from the human: (i) aorta, (ii) pulmonary artery and (iii) superior vena cava were utilized to simulate pulsatile flow conditions within a bioreactor that housed 3 tissue specimens. Results were compared to non-physiological pulsatile flow (NPPF) and cyclic flexure-steady flow (Flex-Flow) conditions. The oscillatory shear index (OSI) was used to quantify the fluid-induced oscillations occurring on the specimen surfaces. The range of mean OSI under the physiological conditions investigated was found to be 0.18 ≤ OSI ≤ 0.23. On the other hand, NPPF and Flex-Flow environments yielded a mean OSI of 0.37 and 0.11 respectively, which were 46% higher and 45% lower than physiological conditions. Moreover, we subsequently conducted OSI-based human bone marrow stem cell (HBMSC) culture experiments which resulted in preferential valvular gene expression and phenotype (significant upregulation of BMP, KLF2A, CD31 and α-SMA using an OSI of 0.23 in comparison to a lower OSI of 0.10 or a higher OSI of 0.38; p <.05). These findings suggest that a distinct range or a “sweet-spot” for physiological OSI exists in the mechanical conditioning of tissue engineered heart valves grown from stem cell sources. We conclude that in vitro heart valve matrix development could be further enhanced by simultaneous exposure of the engineered tissues to physiologically-relevant magnitudes of both fluid-induced oscillations and shear stresses.

    Original languageAmerican English
    Pages (from-to)40-48
    Number of pages9
    JournalJournal of Biomechanics
    Volume65
    DOIs
    StatePublished - Oct 7 2017

    Bibliographical note

    Publisher Copyright:
    © 2017 Elsevier Ltd

    Funding

    Funding for this study from a Coulter Seed grant by the Department of Biomedical Engineering at Florida International University is gratefully acknowledged. We would also like to acknowledge NSF FGLSAMP FIU Bridge to the Doctorate award HRD #1301998 to support Sana Nasim.

    FundersFunder number
    Coulter
    NSF FGLSAMP FIU Bridge
    Division of Human Resource Development1301998
    Biomedical Engineering Department, University of Michigan

      ASJC Scopus Subject Areas

      • Biophysics
      • Biomedical Engineering
      • Orthopedics and Sports Medicine
      • Rehabilitation

      Keywords

      • Oscillatory shear stress (OSS)
      • Pulsatile flow
      • Stem cells
      • Valvular phenotype
      • Tissue engineered heart valves (TEHVs)
      • Oscillatory shear index (OSI)
      • Physiologically-relevant

      Disciplines

      • Engineering
      • Medicine and Health Sciences

      Fingerprint

      Dive into the research topics of 'A "sweet-spot" for fluid-induced oscillations in the conditioning of stem cell-based engineered heart valve tissues'. Together they form a unique fingerprint.

      Cite this