Abstract
Context: Pulse oximetry has become mobile with the use of smartphone and Bluetooth wireless technology. This technology offers many benefits but has not been extensively studied. There is a need to further validate its clinimetric properties for health professionals to provide proper guidance to patients. Objective: This investigation assessed the concurrent validity of the iSpO2 pulse oximeter against a traditional pulse oximeter in measuring short-term resting blood oxygen saturation (SpO2) and pulse rate. Design: Observational study of reliability. Setting: University kinesiology laboratory. Participants: Thirty healthy, recreationally active adults (18 men, 12 women; mean age = 25.7 ± 5.46 years, mean height = 170.3cm ± 9.51, mean body mass = 76.4 kg ± 19.33). Intervention: Resting measurement of SpO2 and pulse rate using the iSpO2 pulse oximeter with the iPad Mini and a traditional pulse oximeter with Bluetooth. Main Outcome Measure: Resting SpO2 and pulse rate were concurrently measured over 5 min. Results: The concurrent validity between the iSpO2 and traditional pulse oximeter was moderate for measuring SpO2, intraclass correlation coefficient (ICC)(3, 1) =.73, SEM = 0.70%, and good for pulse rate, ICC(3, 1) =.97, SEM = 1.74 beats per minute (bpm). The minimal detectable change at the 95% confidence interval for both instruments suggests that there may be 1.94% disagreement for SpO2 and 4.82 bpm disagreement between pulse oximetry methods. The 95% limits of agreement (LoA) for measuring SpO2 suggests that the iSpO2 and traditional pulse oximeters may vary -0.28 ± 1.98%, or approximately 2%. The 95% LoA for measuring pulse rate suggests that the iSpO2 and traditional pulse oximeter may vary 1.74 ± 4.98 bpm, potentially upward of 6 bpm. On the basis of the results of the LoA, it appears that there may be a slight systematic bias between the two devices, with the traditional pulse oximeter producing higher pulse rates than the iSpO2. Conclusion: The findings suggest that both instruments may be beneficial for indirect shortterm measurements of resting SpO2 and pulse rate. © 2014 Human Kinetics.
| Original language | English |
|---|---|
| Pages (from-to) | 37-42 |
| Number of pages | 6 |
| Journal | International Journal of Athletic Therapy and Training |
| Volume | 19 |
| Issue number | 3 |
| DOIs | |
| State | Published - May 2014 |
ASJC Scopus Subject Areas
- Orthopedics and Sports Medicine
- Physical Therapy, Sports Therapy and Rehabilitation
- Rehabilitation
Keywords
- Mobile technology
- Pulse oximetry
- Pulse rate
Disciplines
- Physical Therapy
- Orthopedics
- Sports Medicine
Fingerprint
Dive into the research topics of 'Concurrent validity of arterial blood oxygen saturation measurements: A preliminary analysis of an iPad pulse oximeter and traditional pulse oximeter using Bluetooth'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS