Abstract
A sensitive liquid chromatographic (LC) method using electrochemical detection was developed for the identification and quantitation of cisapride in serum. The serum samples were deproteinized by a simple acetonitrile precipitation technique followed by n-hexane extraction. Cisapride in the deproteinized serum was separated by an isocratic elution with an ODS Hypersil LC column (150 × 4.6 mm) using a mobile phase consisting of 0.05M Na2HPO4-acetonitrile (60 + 40), pH 8.4. Cisapride eluted from the column was detected by a Coulochem II electrochemical detector. The precision of this assay method was determined by intra- and inter-day analyses of cisapride-free fetal bovine serum samples that were spiked with 25, 50, and 100 ng/mL cisapride. For the intra-day assay, recoveries were 94.3 ± 1.4, 90.1 ± 2.9, and 103.2 ± 9.2%, respectively. This electrochemical detection LC method could be very useful in monitoring plasma levels of cisapride.
| Original language | English |
|---|---|
| Pages (from-to) | 9-12 |
| Number of pages | 4 |
| Journal | Journal of AOAC International |
| Volume | 84 |
| Issue number | 1 |
| DOIs | |
| State | Published - Jan 1 2001 |
ASJC Scopus Subject Areas
- General Medicine
Keywords
- Chromatography, Liquid
- Cisapride/blood
- Gastrointestinal Agents/blood
- Humans
- Indicators and Reagents
- Reproducibility of Results
- Serotonin Agents/blood
- Spectrophotometry, Ultraviolet
Disciplines
- Medicine and Health Sciences