Abstract
Full-arch implant-supported restorations using a metal-acrylic resin design have had a high success rate but are also associated with frequent technical complications including framework misfit due to casting errors, debonding of denture teeth, and fracture of the acrylic from the metal framework. This clinical report describes a case of maxillary and mandibular full-arch implant-supported rehabilitation associated with technical and biological complications and use of digital technology for fabricating monolithic restorations. The use of a bio-functional try-in and its subsequent use as a conversion prosthesis for fabricating a master cast is described. The use of the patient's existing metal bar to fabricate a retread type prosthesis is also described along with using digital technology for fabricating a new metal bar and a monolithic type of restoration. The integration of digital and conventional workflows to obtain an increased level of accuracy and simplicity is also discussed.
| Original language | English |
|---|---|
| Pages (from-to) | 483-487 |
| Number of pages | 5 |
| Journal | Journal of Prosthodontics |
| Volume | 28 |
| Issue number | 5 |
| DOIs | |
| State | Published - Jun 2019 |
Bibliographical note
Publisher Copyright:© 2019 by the American College of Prosthodontists
ASJC Scopus Subject Areas
- General Dentistry
Keywords
- CAD/CAM dentures
- hybrid dentures
- monolithic
- retread
Fingerprint
Dive into the research topics of 'Management of Biotechnical Complications Associated with a Full-Arch Implant Restoration Using Digital and Conventional Workflows: A Clinical Report'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS