Abstract
Background: Tissue dielectric constant (TDC) measurements are increasingly being used as a tool to help characterize lymphedema features, detect its presence, and assess treatment related changes. Although the underlying physics of this technology has been well described in the literature, there has been little systematic study of in vivo reliability aspects. A central unanswered question is the minimal detectable change (MDC) that, with a given level of confidence, may be ascribed to this technology. Our goal was to address this issue using test-retest measurements from which intraclass correlations coefficients (ICC) and MDC could be estimated. Methods and Results: Forty volunteers (20 females) aged 19-61 years with body mass indices of 14.7-47 kg/m2 and body fat percentages of 12.0%-48.9% were evaluated. Two measurers (M1 and M2) used two different TDC measuring devices (multiprobe and compact) to measure TDC in triplicate sequentially and bilaterally at three locations; anterior forearm, hand palmar mid-thenar eminence, and dorsum mid-web. These measurements were made by each measurer twice constituting test-retest values (T1 and T2). From these measurements ICC2,1 and MDC at 95% confidence were determined for each site and probe for absolute TDC values and for inter-side ratios. MDC values for absolute TDC ranged from 2 to 9 TDC units, and for inter-side ratios ranged from 5.3% to 8.0% depending on site and probe. ICC2,1 values ranged from 0.765 to 0.982. Conclusions: The MDC values herein documented may be used to provide guidance to aid interpretation of measured TDC changes or differences in a clinical environment
| Original language | English |
|---|---|
| Pages (from-to) | 322-328 |
| Number of pages | 7 |
| Journal | Lymphatic Research and Biology |
| Volume | 17 |
| Issue number | 3 |
| DOIs | |
| State | Published - Jun 2019 |
Bibliographical note
Publisher Copyright:© 2019, Mary Ann Liebert, Inc., publishers 2019.
ASJC Scopus Subject Areas
- Cardiology and Cardiovascular Medicine
Keywords
- lymphedema measurement
- measurement reliability
- minimum detectable change
- minimum detectable difference
- tissue dielectric constant
Disciplines
- Cardiology
Fingerprint
Dive into the research topics of 'Minimum Detectable Changes Associated with Tissue Dielectric Constant Measurements as Applicable to Assessing Lymphedema Status'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS