Skip to main navigation Skip to search Skip to main content

The Effect of Osteotomy Preparation Techniques and Implant Diameter on Primary Stability and the Bone-Implant Interface of Short Implants (6 mm)

Research output: Contribution to journal › Article › peer-review

Abstract

Purpose: To evaluate the effect of osteotomy preparation techniques and implant diameter on primary stability and the bone-implant interface of short implants (6 mm) when placed in bone with a high degree of cancellous content. Materials and Methods: Overall, 90 short dental implants (6 mm; Astra Tech Implant System EV, Dentsply Sirona) were divided into nine groups based on width (narrow implants [N]: 4.2 mm; regular implants [R]: 4.8 mm; or wide implants [W]: 5.4 mm), and the type of osteotomy preparation used (standard [ST], osteotome [OT], or osseodensification [OD]) to be placed in porcine tibia plateau bone samples. The following groups were created: group N-ST, group N-OT, group N-OD, group R-ST, group R-OT, group R-OD, group W-ST, group W-OT, and group W-OD. The insertion torque and implant stability quotient (ISQ) were measured. Additionally, four implants from groups N-ST, N-OT, and N-OD were evaluated histomorphometrically. Results: The insertion torque was significantly higher for implants in group W-OD compared to group W-ST (50.00 ± 14.14 Ncm vs 28.00 ± 10.85 Ncm; P =.005). Similarly, the insertion torque was significantly higher for implants in group W-OT compared to group W-ST (46.87 ± 17.10 Ncm and 28.00 ± 10.85 Ncm, respectively; P =.026). The insertion torque was also significantly higher for implants in group W-OD compared to group N-OD (50.00 ± 14.14 Ncm and 31.5 ± 15.82 Ncm, respectively; P =.04). No significant differences were observed for the percentage of bone marrow space and connective tissue in contact with the implant surface between studied groups. Conclusions: Osteotomy preparation technique in sites with a high degree of cancellous content was found to influence the implant insertion torque for short and wide implants (5.4 × 6 mm). Implant width was found to influence the insertion torque of short implants placed with the OD technique.

Original languageAmerican English
Pages (from-to)27-32
Number of pages6
JournalInternational Journal of Oral and Maxillofacial Implants
Volume40
Issue number1
DOIs
StatePublished - 2025

Bibliographical note

Publisher Copyright:
© 2025 by Quintessence Publishing Co Inc.

ASJC Scopus Subject Areas

  • Oral Surgery

Keywords

  • bone
  • histology
  • implants
  • osseodensification
  • osteotome
  • stability

Disciplines

  • Oral and Maxillofacial Surgery

Fingerprint