The reliability, minimal detectable change and concurrent validity of a gravity-based bubble inclinometer and iphone application for measuring standing lumbar lordosis

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: To investigate the reliability, minimal detectable change (MDC90) and concurrent validity of a gravity-based bubble inclinometer (inclinometer) and iPhone® application for measuring standing lumbar lordosis. Methods: Two investigators used both an inclinometer and an iPhone® with an inclinometer application to measure lumbar lordosis of 30 asymptomatic participants. Results: ICC models 3,k and 2,k were used for the intrarater and interrater analysis, respectively. Good interrater and intrarater reliability was present for the inclinometer with Intraclass Correlation Coefficients (ICC) of 0.90 and 0.85, respectively and the iPhone® application with ICC values of 0.96 and 0.81. The minimal detectable change (MDC90) indicates that a change greater than or equal to 7° and 6° is needed to exceed the threshold of error using the iPhone® and inclinometer, respectively. The concurrent validity between the two instruments was good with a Pearson product-moment coefficient of correlation (r) of 0.86 for both raters. Ninety-five percent limits of agreement identified differences ranging from 9° greater in regards to the iPhone® to 8° less regarding the inclinometer. Conclusion: Both the inclinometer and iPhone® application possess good interrater reliability, intrarater reliability and concurrent validity for measuring standing lumbar lordosis. This investigation provides preliminary evidence to suggest that smart phone applications may offer clinical utility comparable to inclinometry for quantifying standing lumbar lordosis. Clinicians should recognize potential individual differences when using these devices interchangeably.

Original languageEnglish
Pages (from-to)62-67
Number of pages6
JournalPhysiotherapy Theory and Practice
Volume30
Issue number1
DOIs
StatePublished - Jul 17 2013

ASJC Scopus Subject Areas

  • Physical Therapy, Sports Therapy and Rehabilitation

Keywords

  • Inclinometer
  • Range of motion
  • Smart phone
  • Spine

Disciplines

  • Physical Therapy

Fingerprint

Dive into the research topics of 'The reliability, minimal detectable change and concurrent validity of a gravity-based bubble inclinometer and iphone application for measuring standing lumbar lordosis'. Together they form a unique fingerprint.

Cite this